P產品分類RODUCT CATEGORY
相關文章 / ARTICLE
品牌 | 銀順 | 線芯材質 | 裸銅絲 |
---|---|---|---|
絕緣材質 | 聚乙烯 | 護套材質 | 聚氯乙烯 |
額定電壓 | 8.7/10kv |
標題:8.7/10kv高壓電力電纜YJV-1*25
產品概述
8.7/10kv高壓電力電纜YJV-1*25
6kV~35kV 中低壓銅芯及鋁芯交聯聚乙烯絕緣電力電纜(YJV電纜,YJV22電纜,YJLV電纜,YJLV22電纜) XLPE Insulated Power Cable | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
交聯聚乙烯絕緣電力電纜是采用化學方法或物理方法,使聚乙烯分子由線型分子結構轉變為三維網狀結構,由熱塑性的聚乙烯變成熱固性的交聯聚乙烯,從而提高了聚乙烯的耐老化性能、機械性能和耐環境能力,并保持了優良的電氣性能。 交聯聚乙烯絕緣電力電纜導體的允許長期最高溫為90攝氏度,較低絕緣電纜、聚氯乙烯絕緣電纜和聚乙烯絕緣電纜高,且具有重量輕、結構簡單、使用方便、耐化學腐蝕和敷設不受落差限制等優點。 26/35KV電力電纜,18/30KV交聯電纜,12/20KVYJV電纜,8.7/15KVYJV22電纜線,6/10KV鋁芯交聯電纜線,3.6/6KVYJLV單芯電纜 中低壓交聯電纜產品標準 Standard 本產品按GB12706《額定電壓35V及以下銅芯、鋁芯塑料絕緣電力電纜》標準生產,同時還可根據用戶需要按國際電工委員會推薦標準IEC、英國標準、德國標準及美國標準生產。 The product is manufactured according to the standard of《GB12706 or IEC、BS、DIN and ICEA upon request. 適用范圍 Applications 本產品適用于工頻額定電壓3.6/6kv~26/35kv輸配電線路作配送電能子用。 The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv. 使用特性 Operating characteristics · 工頻額定電壓U0/U為3.6/6kv~26/35kv。 Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv. · 電纜導體的最高允許工作溫度:90℃。 Max.admissible operating temperature of the conductor:90℃. · 短路時(最長時間不超過5s)電纜導體的最高溫度不超過2500C。 Max. short-circurt temperature of conductor shall not exceed 2500C. (5s maximum duration) · 電纜敷設時環境溫度應不低于00C。 The ambient temperature under installation should not below 00C. · 電纜彎曲半徑:三芯電纜不小于電纜外徑15倍;單芯電纜不小于電纜外徑20倍。 The bending radius of a single-core cable should not less than 20 times of the cable diameter. The bending radius of a single-core cable should not less than 15 times of the cable diameter. 電纜額定電壓的選擇 Voltage designation · 電纜的額定電壓應適合于電纜系統的運行狀況,用U0/U(Um)kv表示。 U0-電纜設計用的導體對地或金屬屏蔽之間的額定工頻電壓; U-電纜設計用的導體間的額定工頻電壓; Um-設備可承受的“最高系統電壓"的最大值。 The rated voltage of the cable for a given applixation shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the form of U0/U(Um)kv Where: U0-The rated power-frequency voltage between conductors and earth metallic screen ,for which the cable designed; U - The rated power-frequency voltage between conductos, for which the cable designed; Um- The maximum value of the“highest system voltage"for which the equipment may beused. · 三相系統用電纜的U0值推薦如下表: The values of U0 recommened for cable to be used in three-phase systems are listed below:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
A類系統──該類系統任何一相導體與地和接地導體接觸時,能在1min內與系統分離 B類系統──該類系統僅包括單相接地故障短時運行的條件,接地故障時間應不超過1h, 但在任何情況下,最長不超過8h每年接地故障總持續時間不超過125h; C類系統──不屬于A類、B類的系統。 System category A──This category comprises those systems in which any phase conductor that comes in contact with earth or an earth conductor. is disconnected from the system within 1 min. System category B ──This category comprises those system which,under faultconditions,are operated,are operated for ashorttimewith one phase earthed.This period should not exceed 1 h..Fora longer period, not exceeding 8h on any occasion, can be tolerated.The total duration of earth faults in any year should not exceed 125h. System categeory C──This category comprises all systems which do not fall into A and B 電纜的型號Type of cable | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
生產范圍Production range of cable | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
8.7/10kv高壓電力電纜YJV-1*25